OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.